As a designer and manufacturer of thermocouples, the most commonly asked question we receive is: How long should my thermocouple last?
Unfortunately, the answer to this question is quite complex and is dependent on a host of variables, not all of which may be obvious. At the root of the complexity are often unseen or unanticipated factors that may have a major effect on the sensor's usable lifespan.
Essentially, every application has its own intricacies, and their impact on operational and environmental factors are not always considered or understood to specify a proper thermocouple design. To underscore the impact of often unseen or unknown factors, the following are a few application scenarios of which we have collaborated with our customers.
Application Example 1
Our first example is from an emergency call we received from a large company with multiple locations. They were suddenly seeing massive product deviations from their box-anneal operation. Their downstream product users were reporting their materials to be overheating by more than 100°F. The financial loss was substantial and growing by the day.
Responding immediately, we spent two days inspecting rows of furnaces, sensors and operational details. One of the questions asked of different operators was: "How often do you change out your Inconel protection tubes?" The operators' repeated response was: "Our preventive-maintenance schedule calls for change-out once every 12 months."
The tubes appeared to be in good condition, but upon closer examination they exhibited signs of unusual age. One of the metal protection tubes was removed from service and was cut off about 3 inches from the hot end. Looking into the cut piece, the tube appeared as a clogged artery lined with plaque. There was a very thick lining of inky-black carbon. This indicated that the tube had not been replaced in several years.
Upon reviewing the maintenance logs, it was discovered that there was a lapse in tube replacement going back over three years. In effect, new thermocouples were installed into contaminated tubes, causing the degradation of the sensors and generating greater than a 100°F shift in accuracy. In this scenario, thermocouple life, which should have been close to one year, was shortened to within a week.
Application Example 2
Another example of unseen forces impacting the accuracy...