Introduction
Fixed orthodontic appliances considerably increase plaque accumulation, alter the gingival and plaque index, and impede oral hygiene [1]. Most orthodontists recommend their patients to use fluoride-containing regimens additionally along with daily brushing and flossing procedures during orthodontic treatment to prevent tooth decay [2]. While there are numerous commercially available antimicrobial mouthwashes on the market, sodium fluoride (NaF) is the most widely used rinsing agent and has some negative effects on orthodontic materials [3]. During ancient times some ayurvedic procedures like oil pulling were likely used as an adjuvant for oral hygiene practices [4]. Oil-pulling therapy involves some oils like coconut oil, olive oil, sesame oil, etc., which were advised for mouth rinsing in the early mornings on an empty stomach for 20 minutes [5]. Incorporating ozone into mouth rinsing has recently been shown to be more helpful than traditional therapy methods, which adopt a minimally invasive and conservative approach to dental treatment and are inexpensive [6]. There was strong proof that human oral epithelial cells, periodontal cells, and gingival fibroblast were biocompatible with ozonated oil [7]. Many studies explained the anti-microbial action of ozone-infused oral rinses but, none of the studies explained their action on fixed orthodontic appliances, especially the archwires which are placed over a long span. In this study, NaF and ozone-infused oil-pulling solution with coconut oil (O3) mouth rinsing agents were preferred over the other commercially available rinses due to their good resistance to bacterial count, unique properties, and beneficial effects. All orthodontic archwires were utilized to project forces, but copper-nickel-titanium (Cu-Ni-Ti) archwires produce forces that are more accurate and consistent over a longer duration. Due to its availability at several phase transformation temperatures (15oC, 27oC, 35oC, and 40oC), the clinician can choose the appropriate archwire for each individual situation [8]. Due to the long interval stay of these wires in patient’s mouths, and exposure to mouth rinses, there could be changes in the wire characteristics. There was little information available on the potential effects of mouthwashes over Cu-Ni-Ti archwires. As a result, the goal of this in-vitro investigation is to assess how 0.05% NaF mouthwash and O3 solution affect the mechanical properties and surface characterization of Cu-Ni-Ti archwires.
Materials and methods
Methodology
Considering the preliminary data acquired, power analysis at 80%, and fixing the confidence level at 95%, a sample size of 60 was fixed for this study. A total of three groups (n=20 each) meet the constraints of α = 0.05. Of the 20 samples in each group, 15 samples were for determining the mechanical properties, and the rest five were for observing the surface characteristics of the archwires when subjected to various mouth rinses. Review board clearance from the GSL Educational Institution was obtained for the use of the study (GSLEI/IRB/2019/003). Sixty samples of 0.016” preformed maxillary Cu-Ni-Ti type 35oC (Ormco Company, USA) archwires were cut from the posterior part of the straight ends for a length of 25 mm. These wires were randomly distributed into three groups. Each group was incubated at 37oC in a separate sterile petri dish with 10 mL of 0.05% NaF mouthwash (ACT Anti-Cavity Fluoride Mouthwash, Sanofi Company, USA), O3 (O3 Essentials, Health Ranger Store, USA) and distilled water (dH2O) (control solution) for 90 minutes in an incubator. According to Mary P Walker et al., (2005), this period of time would be comparable to three months of using topical fluoride or fluoride mouthwashes for one minute each day [9]. Before being put through mechanical testing, samples from the various experimental groups were cleansed with dH2O and transferred to new containers with labels for their respective groups. A three-point bend test was performed on all the samples on a universal testing machine (UTES-40-HGFL) with a 5 kN load cell. On the machine, the two poles were spaced 12 mm apart in the lower jaw, which simulated the inter-bracket distance between the teeth. A steel rod with a bevel end chisel was positioned halfway between the two poles and a compressive force at a crosshead speed of 0.5 mm/min was applied. Each sample was loaded to a deflection of 3.1 mm and then unloaded to zero deflection at a crosshead speed of 2.5 minutes [9]. Using computer software, each sample's load in newtons (N) and deflection in millimeters were recorded during both loading and unloading. The data was used to produce load-deflection curves, and the engineering beam theory was applied to determine the yield strength (YS) and the flexural modulus of elasticity (E). The springback ratio (YS/E) was calculated based on the data obtained [10]. The loading curves obtained from the three-point bending test simulate the activation of the wire, whereas the unloading curves depict deactivation forces which provide an indication of its potential clinical behaviour.
Evaluation of surface characterization
The surface properties of the archwires were evaluated using a scanning electron microscope (SEM) (Hitachi, S-3700N) at an x1000 magnification. Each sample was put on a holder and examined with a field-emission SEM device. The archwire surface was bombarded with electrons, and each pixel on the SEM image was examined for the electron reflection intensity. Based on a visual assessment of the surface irregularities, the surface topographical characteristics were established [9].
The obtained information was computed using IBM Statistical Package for Social Sciences (SPSS) version 20 (Armonk, NY, USA) software. The statistical analysis carried out included the means and standard deviations of all the variables. Kolmogorov-Smirnov test was used to investigate the normality of the data obtained. One-way analysis of variance (ANOVA) was done with a 5% level of significance (α =.05) for both the loading and unloading of the archwire. YS, E, and YS/E for each sample were recorded and compared to see if there were any notable variations between the groups. Tukey’s post hoc tests for multiple pairwise comparisons were done to analyze the data.
Results
Normality in the distribution of data was observed in regard to the parameters (Table 1).
Table 1
Distribution of data with regard to all the study parameters
Parameter | Kolmogorov-Smirnov statistic | Df | P value | |
Loading | Yield strength (MPa) | 0.1 | 45 | 0.2 |
Modulus of elasticity (GPa) | 0.106 | 45 | 0.2 | |
Springback ratio | 0.099 | 45 | 0.2 | |
Unloading | Yield strength (Mpa) | 0.114 | 45 | 0.17 |
Modulus of elasticity (GPa) | 0.106 | 45 | 0.2 | |
Springback ratio | 0.106 | 45 | 0.2 |
On mechanical testing, it was noted that all three groups, including the control, displayed statistical significance for both loading and unloading features (Table 2).
Table 2
Comparison of loading and unloading mechanical properties between control and experimental group
One-way analysis of variance (ANOVA) was performed to compare the mechanical parameters of loading and unloading between the experimental and control groups
Parameter | Distilled water | Ozone-infused oil-pulling solution with coconut oil | Sodium fluoride mouthwash | |
Yield strength (MPa) | Loading | 1188.85 ± 22.71 | 1146.77 ± 23.16 | 1105.63 ± 26.11 |
Unloading | 683.59 ± 13.06 | 653.65 ± 13.2 | 630.2 ± 14.88 | |
Modulus of elasticity (GPa) | Loading | 70.08 ± 2.67 | 65.2 ± 2.63 | 60.02 ± 2.84 |
Unloading | 66.9 ± 2.55 | 62.27 ± 2.51 | 57.8 ± 2.71 | |
Springback ratio | Loading | 0.0016 ± 0.0003 | 0.0017 ± 0.0003 | 0.0018 ± 0.00043 |
Unloading | 0.0102 ± 0.0002 | 0.0105 ± 0.0002 | 0.0109 ± 0.00026 |
The data were analyzed using Tukey's post hoc testing for multiple pairwise comparisons. The results from the control group showed a significant difference between the O3 solution and NaF, indicating that both mouthwashes reduced the mechanical properties of Cu-Ni-Ti wires during loading and unloading (Table 3).
Table 3
Multiple pairwise comparisons of mechanical properties on loading and unloading between the study groups
Tukey's post hoc analysis was used to compare mechanical parameters during loading and unloading between the research groups for pairwise comparisons; * denotes statistical significance
Parameter | Reference group | Comparison group | Loading | Unloading | ||
Mean difference | P value | Mean difference | P value | |||
Yield strength (MPa) | Distilled water | Ozone-infused oil-pulling solution with coconut oil | 42.08 | <0.001* | 29.93 | <0.001* |
Sodium fluoride mouthwash | 83.22 | <0.001* | 53.38 | <0.001* | ||
Ozone-infused oil-pulling solution with coconut oil | Sodium fluoride mouthwash | 41.14 | <0.001* | 23.45 | <0.001* | |
Modulus of elasticity (GPa) | Distilled water | Ozone-infused oil-pulling solution with coconut oil | 4.87 | <0.001* | 4.65 | <0.001* |
Sodium fluoride mouthwash | 9.45 | <0.001* | 9.03 | <0.001* | ||
Ozone-infused oil-pulling solution with coconut oil | Sodium fluoride mouthwash | 4.58 | <0.001* | 4.38 | <0.001* | |
Springback ratio | Distilled water | Ozone-infused oil-pulling solution with coconut oil | -0.0006 | <0.001* | -0.0002 | 0.004* |
Sodium fluoride mouthwash | -0.0013 | <0.001* | -0.0006 | <0.001* | ||
Ozone-infused oil-pulling solution with coconut oil | Sodium fluoride mouthwash | -0.0006 | <0.001* | -0.0004 | <0.001* |
Discussion
Demineralization is a natural side effect of fixed orthodontic therapy, particularly when it is combined with bad oral hygiene. White spot lesions and consequent enamel demineralization are caused by the acidic byproducts of the bacterial consortia in plaque [11]. Orthodontists commonly prescribe daily topical fluoride to prevent plaque accumulation, and demineralization of tooth structure [2]. However, these prophylactic agents get in constant touch with the components of fixed orthodontic appliances like brackets, archwires, etc., which in turn results in the disruption of the titanium oxide layer on nickel-titanium alloys. This leads to changes in the mechanical properties and surface of the archwire, as the alloy loses its passivating effect and hydrogen embrittlement, thereby hindering the treatment outcome of the orthodontic archwires [12]. The current study findings revealed that dH2O has a statistically significant (<0.001) difference in terms of higher YS, E, and YS/E when compared to NaF mouth rinse. However, M Kaushik et al., (2011) observed a significant change only in the unloading mechanical properties between NaF mouth rinse and dH2O [5]. They stated that the difference in YS may be due to NaF and its additives which may cause the deterioration of Cu-Ni-Ti archwires. The change in the E may be due to titanium hydride formation at interstitial regions of a crystal lattice. Additionally, they noted that titanium hydrides were thought to create a body-centered tetragonal structure, which was the primary factor altering the alloy's mechanical properties. The present study agrees with the reasoning given by M Kaushik et al., (2011) regarding the change in mechanical properties of Cu-Ni-Ti archwires when exposed to NaF compared with dH2O [5]. A similar explanation was given by Mary P Walker et al. (2005) for both loading and unloading forces but there was no statistically significant difference in the mechanical properties mentioned [9]. They claimed that when Ni-Ti and Cu-Ni-Ti archwires are subjected to fluoride rinses, hydrogen absorption and embrittlement of titanium-based alloys are detected. Titanium typically has a surface oxide layer that blocks hydrogen from penetrating and prevents the creation of ionizable fluoride compounds, but when fluoride elements like sodium fluoride and hydrogen fluoride are exposed, this layer is activated, which leads to fast corrosion. The addition of Cu in Cu-Ni-Ti wires serves as a relative inhibitor of reducing acids like hydrogen fluoride. As a result, less titanium hydride will form in the lattice structure, which will help to keep the wire's mechanical properties from changing. Distilled water didn’t have any fluoride agents in it; so, it offers less alteration in mechanical properties of Cu-Ni-Ti archwires when compared with fluoride rinses. In contrast to the findings of the present work, Arthi Ramalingam et al., (2008) showed that after immersing Cu-Ni-Ti in dH2O and NaF mouthwash, there was no significant difference in YS and E considering both loading and unloading forces [13]. In the present study, when the mean values are compared it shows that both in loading and unloading, dH2O offers more YS, E, and YS/E with a statistical significance of <0.001. There haven't been any contradictory studies on the influence of O3 and dH2O on the mechanical characteristics of Cu-Ni-Ti archwires under loading and unloading stresses up to this point. When compared with dH2O, there is a higher degree of change observed in the mechanical properties during loading and unloading forces of Cu-Ni-Ti archwires after immersion in O3 was observed. Generally, ozone is an easily soluble oxidizing molecule that can be dissociated into unstable nascent oxygen and oxygen molecule; so, ozone is delivered by means of ozonated water or oil forms. L Zhu et al., (2004) stated that when titanium reacts with oxygen, it forms a titanium dioxide (TiO2) layer at more than 400oC [14]. Moreover, the TiO2 layer acts as a protective layer which prevents further corrosion. However, In the current study, Cu-Ni-Ti archwires are subjected to ozone-infused coconut oil pulling solution at 37oC only; so, ozone might not alter Cu-Ni-Ti archwire mechanical properties. The change in the mechanical properties may be because of other ingredients which are present in ozone-infused coconut oil pulling solution. Moreover, the effect of coconut oil on fixed orthodontic materials was nowhere elucidated in the literature to date. In the present study, when the mean values are compared, it shows that both in loading and unloading, O3 offers more YS, E, and YS/E with a statistical significance of <0.001. There are no confounding articles present regarding the comparison of mechanical properties of Cu-Ni-Ti archwire after immersion in O3 and NaF mouthwash.
An SEM was used to determine the qualitative assessment of constituent elements in the alloys [15]. When viewed at x1000 magnification in SEM during the current study, the archwire surface exposed to dH2O appeared to have a lot of dark spots on the Cu-Ni-Ti wire surface (Figure 1).
Figure 1
Surface topography of copper-nickel-titanium wires exposed to distilled water
The current study's findings agreed with those of M Kaushik et al., (2011) and Mary P Walker et al., (2005) [5, 9]. They claimed that the coating of byproducts applied to the Cu-Ni-Ti and Ni-Ti archwires during the production process may have been the cause of the alteration in the surfaces of those materials.
Cu-Ni-Ti archwires when subjected to NaF mouth rise observed in SEM at x1000 magnification exhibit an enlarged bright white patch with globular, pitted, and elongated flaws and a much larger exposure of white inclusions (Figure 2).
Figure 2
Surface topography of copper-nickel-titanium wires subjected to sodium fluoride mouthwash
The findings of the present study were in accordance with M Kaushik et al., (2011) [5]. The investigation by Mary P Walker et al., (2005) observed that pitting emerges along the wire's wrought surface and noted that the pH and fluoride concentration of the preventive agent affects the fluoride-related alloy [9]. According to the findings of the current study, the components of NaF mouthwashes (sodium or fluoride) were to blame for the disintegration of the titanium oxide layer on Cu-Ni-Ti arch wires, which resulted in corrosive alterations.
A mottled, pitted appearance in addition to dark smudge patches was seen at x1000 magnification under an SEM for the Cu-Ni-Ti archwires after being submerged in an O3 solution (Figure 3).
Figure 3
Surface topography of copper-nickel-titanium wires subjected to ozone-infused oil-pulling solution with coconut oil
In the present study after immersion of Cu-Ni-Ti archwire in NaF, the surface of the archwire showed bright white spots, pitting with appreciated defects that were not clearly observed in dH2O. In the current study, exposure to NaF resulted in more corrosive changes than in the control group. Comparing the experimental groups, after immersion of Cu-Ni-Ti archwire in NaF mouthwash, the archwire exhibited pitting with clearly demarcated bright white spots with dark smudges. However, these findings are less observed in O3 solutions.
Limitations
As this is an in vitro investigation, the results cannot be directly compared to clinical performance. Variations in the experimental conditions might differ in the shear bond strength (SBS) values. Mechanical properties and surface characteristics of Cu-Ni-Ti archwires might differ from in vivo to in vitro.
Further scope
As the oral conditions influence the mechanical properties and surface characteristics, further clinical studies are necessary for validation, especially for O3 solutions.
Conclusions
On exposure to sodium fluoride mouthwash and ozone-infused oil-pulling solution with coconut oil, the mechanical properties during loading and unloading of 0.016” copper-nickel-titanium archwires were altered. Sodium fluoride mouthwash showed more deleterious changes in the mechanical properties of copper-nickel-titanium archwires while ozone-infused oil-pulling solution with coconut oil showed lesser changes. Sodium fluoride mouthwash offers more corrosive changes when compared with the ozone-infused oil-pulling solution with coconut oil.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer
Copyright © 2023, Sukumar et al. This work is published under https://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Abstract
Aims and objectives: To determine the impact on the mechanical properties and surface characteristics of prefabricated 0.016" copper-nickel-titanium (Cu-Ni-Ti) type 35oC (Ormco Company, USA) archwires when subjected to 0.05% sodium fluoride (NaF) mouthwash (ACT Anti-Cavity Fluoride Mouthwash, Sanofi Company, USA) and ozone-infused oil-pulling solution with coconut oil (O3) (O3 Essentials, Health Ranger Store, USA).
Materials and methods: Sixty samples of preformed maxillary 0.016” Cu-Ni-Ti archwires were cut at the straight posterior ends for a length of 25 mm and then equally distributed into three groups (n=20). Each group of wires was immersed in distilled water (dH2O), NaF, and O3 solutions for 90 minutes at 37oC. All samples were taken out of their solutions and washed with distilled water prior to testing. On a universal testing device, a three-point bending test was performed on 15 samples. Yield strength (YS), flexural modulus of elasticity (E), and springback ratio (YS/E) were calculated. The remaining five samples from respective solutions were observed under a scanning electron microscope (SEM) for surface topography evaluation.
Results: The mean differences in loading YS, E, and YS/E between NaF and O3 are 41.14 MPa, 4.58 GPa, and -0.0006 whereas unloading values are 23.45 MPa, 4.38 GPa, and -0.0004, respectively with a statistical significance of <0.001. Surface topography alteration was appreciated in the NaF mouthwash group compared to the O3 solution.
Conclusions: The mechanical properties of 0.016" Cu-Ni-Ti archwires during loading and unloading were changed after exposure to NaF mouthwash and O3 solution. The mechanical properties of Cu-Ni-Ti archwires were more negatively affected by NaF mouthwash than by O3 solution. Sodium fluoride mouthwash offers more corrosive changes when compared with the O3 solution.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer