Background
Even a small change in the pressure gradient between the venous system and the right atrium can have significant hemodynamic effects. Mean systemic filling pressure (MSFP) is the driving force of the venous system. As a result, MSFP has a significant effect on cardiac output. We aimed to test the hypothesis that the hemodynamic instability during induction of general anesthesia by intravenous propofol administration is caused by changes in MSFP.
Methods
We prospectively collected data from 15 patients undergoing major surgery requiring invasive hemodynamic monitoring. Hemodynamic parameters, including MSFP, were measured before and after propofol administration and following intubation, using venous return curves at a no-flow state induced by a pneumatic tourniquet.
Results
A significant decrease in MSFP was observed in all study patients after propofol administration (median (IQR) pressure 17 (9) mmHg compared with 25 (7) before propofol administration, p = 0.001). The pressure gradient for venous return (MSFP – central venous pressure; CVP) also decreased following propofol administration from 19 (8) to 12 (6) mmHg, p = 0.001. Central venous pressure did not change.
Conclusions
These results support the hypothesis that induction of anesthesia with propofol causes a marked reduction in MSFP. A possible mechanism of propofol-induced hypotension is reduction in preload due to a decrease in the venous vasomotor tone.
You have requested "on-the-fly" machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Show full disclaimer
Neither ProQuest nor its licensors make any representations or warranties with respect to the translations. The translations are automatically generated "AS IS" and "AS AVAILABLE" and are not retained in our systems. PROQUEST AND ITS LICENSORS SPECIFICALLY DISCLAIM ANY AND ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES FOR AVAILABILITY, ACCURACY, TIMELINESS, COMPLETENESS, NON-INFRINGMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Your use of the translations is subject to all use restrictions contained in your Electronic Products License Agreement and by using the translation functionality you agree to forgo any and all claims against ProQuest or its licensors for your use of the translation functionality and any output derived there from. Hide full disclaimer