Full Text

Turn on search term navigation

© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.

Abstract

Measurement of core body temperature—clinical thermometry—provides critical information to anaesthetists during perioperative care. The value of this information is determined by the accuracy of the measurement device used. This accuracy must be maintained despite external influences such as the operating room temperature and the patient’s thermoregulatory defence. Presently, perioperative thermometers utilise invasive measurement sites. The public health challenge of the COVID-19 pandemic, however, has highlighted the use of non-invasive, non-contact infrared thermometers. The aim of this article is to review common existing thermometers used in perioperative care, their mechanisms of action, accuracy, and practicality in comparison to infrared non-contact thermometry used for population screening during a pandemic. Evidence currently shows that contact thermometry varies in accuracy and practicality depending on the site of measurements and the method of sterilisation or disposal between uses. Despite the benefits of being a non-invasive and non-contact device, infrared thermometry used for population temperature screening lacks the accuracy required in perioperative medicine. Inaccuracy may be a consequence of uncontrolled external temperatures, the patient’s actions prior to measurement, distance between the patient and the thermometer, and the different sites of measurement. A re-evaluation of non-contact thermometry is recommended, requiring new studies in more controlled environments.

Details

Title
Are Non-Contact Thermometers an Option in Anaesthesia? A Narrative Review on Thermometry for Perioperative Medicine
Author
Andre van Zundert  VIAFID ORCID Logo  ; Intaprasert, Tonchanok  VIAFID ORCID Logo  ; Wiepking, Floris  VIAFID ORCID Logo  ; Eley, Victoria  VIAFID ORCID Logo 
First page
219
Publication year
2022
Publication date
2022
Publisher
MDPI AG
e-ISSN
22279032
Source type
Scholarly Journal
Language of publication
English
ProQuest document ID
2632745048
Copyright
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.